We specialise in the installation of both Multi-Mode and Single-Mode Fibre-Optic cabling. With design and installation experience on projects covering distances up to 35,000mtrs, we boast the knowledge and expertise to undertake Fibre-Optics work in any environment. Our engineers have installed optical-fibre into some of the UK’s most prestigious and well-known businesses. The constant demand for bigger data transfer, faster networks and building to building connections has pushed Fibre-Optics to become the preferred method of ensuring stability, security, and resilience over vast distances. Oakbank can design, supply, and install robust, future-proof Fibre-Optic solutions into any environment.
All our fibre engineers are accredited with SA002, S7 PIA & K8.
We carry out Acceptance testing / Stage Testing:
Stage A – This test is provided while still on the drum and ensures no damage has occurred during transit, or storage. Without test results at this stage, no responsibility can be accepted by the manufacturer.
Stage B – Laid cable into trench or duct systems, prior to splicing of cable section the test required are for the following:
• Test Equipment: Light Source & Power Meter and or OTDR
• Insertion loss: Of the fibre due to excessive pulling tension or excessive bending.
• ILM testing: One direction would be adequate.
• Test Wavelength: Single fibre testing at 1310 & 1550nm’s to highlight macro bending issues.
Stage C – Final Testing of the completed system with all cable section completed, where the customer requires full and final test results to include OTDR and Loss testing kits (ILM Kit).
• Test Equipment: Light Source & Power Meter and or OTDR
• Insertion loss: Of the fibre due to excessive pulling tension or excessive bending.
• ILM testing: Both directions on all fibres.
• Test Wavelength: Single fibre testing at 1310 & 1550nm’s to highlight macro bending issues.
• OTDR Testing: Tests must be in both directions at both 1310 & 1550nm with all traces and results pertaining to the fibre characteristics test.
• Documentation: Providing all traces and ILM test results, with refractive indexes, cable length also fibre to cable length adjustments with referencing index where fibre length cable length this will assist when damage to fibre occurs to pinpoint exact length to fault.
Key Deliverables:
• 1GB / 10GB / 40GB / 100GB capable Single-Mode and Multi-Mode Optical-Fibre implementation
• State of the art Fibre-Optic Fusion splicing methods ensuring 0dB loss on every termination.
• Fibre-Optic installation into any environment incorporating specialist Steel Armoured / Fire Retardant / Steel Taped / Corrugated Steel Tape sheathed high end Fibre-Optics from the world’s leading manufacturers.
• Light Meter and OTDR bi-directional testing and digital certification
• Fibre-fault finding, repair, replacement service.